Saturday, March 19, 2016

Re:[MW:24549] Is Sensitive leakt test / Pneumatic Test can be considered as Substitute.

Dear Prakash ,

RT is applicable if its a Golden joint .  Hydrotest / pneumatic is done to check the integrity of the whole line.( welds and material ) . There are services which has 100%RT and pneumatic test as well . So I don't think RT is a option.



Sent from my Mi phone
On pkkanishk2006@gmail.com, Mar 19, 2016 12:33 PM wrote:


Dear Members ,

Please clarify that whether in any circumstances we could substitute RT with pressure / any leak test for services where RT is been included as a inspection method.


Regards
Pratish

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/f63a3157-92e6-4f84-aa59-22332c4a67c0%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/jgkgi96u7e5gg7ijuu06reig.1458365157611%40email.android.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35320] Pipe Insert Sleeve - How to ensure after hydrotest No Water

Dear All, Please see below picture  Pipe Insert Sleeve in my site taking trial and completed hydrotest as proto type. Now how to ensure ther...