Dear Ravi Shankar,
-- If we talk as per code requirement than in sec-VIII Div -1 it is mentioned that if the fiber elongation of formed head if greater than 5% then SR is required & generally below 14mm thk plate fiber elongation comes below 5%.
And if left code than it is client requirement.
Thanks & Regards
Amit Mavi.
Sr. Engineer QA/QA & Welding Technologist
Multimax Engineering Works (P) Ltd.
A6 Industrial Estate Partapur Meerut (U.P)
+91-95481444161
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---