Friday, March 18, 2016

Re: [MW:24541] PWHT of branch connections.//B31.3

Dear Sir,

My doubt is, the width of the  band (HB or GCB) along the length of main pipe is on the logic of diminishing temperature and its metallurgical effects. Why not it is not considered to do the pwht of the branch in the vicinity area of branch/RF pad only by the same logic of HB and GCB near the weld area of RF pad/branch.( This will reduce the consumption of power, coiling time etc.)

Thanking you

Hareesh K V

On Mar 18, 2016 9:52 AM, "Raghuram Bathula" <raghurambathula@gmail.com> wrote:
Dear Hareesh

Yes, it is. guidance for placement of thermocouples can be reffered to para 6.6.4 of AWS D10.10
control thermocouples  on larger pipe and monitoring thermocouples  on smaller branch connection


On 18 March 2016 at 06:03, Hareesh K V <hareesh13h@gmail.com> wrote:
Dear Sir,

As per ASME B31.3, for branch connections, PWHT is to be done for the entire circumference of main pipe. Is there any exceptions/code interpretations for that, in Carbon steel material or Alloy steel material (SA335 Gr P9,95)?

For example: A 3/4" branch is done on the main pipe of 60" dia. As per the code requirement, the entire 60" dia is to be wrapped with coil and PWHT is to be done.

Thanks in advance.

Regards,

Hareesh K V

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADxVubmS82tgd6mRushic9Ghu17PsV3anqPmaC%3DXCf9cEi284w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAM3LgAW6LfSNo8q9vMED_K_H2uAmh4hMgQiw4B8UzXgVzveS-w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...