Regards,
Abdul Hafeez
-----Original Message-----
From: c.nopadon@vipco-thai.com
Sent: 27/11/2011 4:38:25 am
Subject: RE: [MW:13064] Type of steel as per chemical proterties
Normal PMI equipment like XRF spectrometer cannot identify C. From my
knowledge , it must be portable spectrometer or similar which will be more
expensive than normal PMI. If PMI is required for stainless of which carbon
content is the issue such as 347H , it is possible that the client will
require PMI result with carbon content.
Regards,
C.Nopadon
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of pankaj abhang
Sent: Saturday, November 26, 2011 1:04 PM
To: materials-welding@googlegroups.com
Subject: Re: [MW:13061] Type of steel as per chemical proterties
Dear How you identified carbon in PMI?..........
Regards,
pankaj
On Fri, Nov 4, 2011 at 11:50 PM, meisam shokri arfaei
<meisamshokri@gmail.com> wrote:
Dear friend,
This material is something like CK30. But this kind of material is heat
treatable and you have to sure about this. It is recommended to have a
metallographic test on it for undrestanding such a heat treatment.
Regards
On Fri, Nov 4, 2011 at 1:22 PM, U WYNN-NAING <u.wynn-naing@total.com> wrote:
Dear Experts,
We did PMI test on one unknown machine bolt from crane boom rest and result
is as follow:
Can someone tell me how can we trace the steel grade base on this result.
Is there any software available?
Thanks and Rgds,
WN
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
<mailto:materials-welding%2Bunsubscribe@googlegroups.com>
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and
meant for educational purposes only, Users must take their own decisions
w.r.t. applicable code/standard/contract documents.
--
M. Shokri Arfaei
International Welding Engineer (IWE)
ASNT NDT Level III
ERI Metallurgy Lab. Manager
Tel: +98-21-66283696
Fax: +98-21-66283693
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
<mailto:materials-welding%2Bunsubscribe@googlegroups.com>
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and
meant for educational purposes only, Users must take their own decisions
w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and
meant for educational purposes only, Users must take their own decisions
w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment