Friday, November 25, 2011

Re: [MW:13051] CALIBRATION OF WELDING MACHINES

U can do it with tong tester. Hold the tong tester in the cable which is connected to you holder. Set 80A, 100A, 120A,140A etc like that three or more u measure in tong tester upto 10A variation ok.Do it witth 2.5mm rod, 3.15mm rod and 4mm rod. Refer the code BS7570:2000 if u need. Tong tester should to be calibrated. Make tong tester zero after every evaluation


From: sajan james <sjnjames@gmail.com>
To: materials-welding@googlegroups.com
Sent: Saturday, June 18, 2011 1:38 AM
Subject: Re: [MW:11353] CALIBRATION OF WELDING MACHINES

You can use BS7570:2000. Code of practice for the validation of arc welding equipment. ... Validation of arc welding equipment.
 
 
Reagrds,


 
On Fri, Jun 17, 2011 at 4:35 PM, mike ball <oiqsnig@yahoo.com> wrote:
Please I require assistance on calibration of welding machines.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...