Is there experiential evidence that flattening tests on SA312 TP304L ¾" sch40 pipe (with D/t ratio = 9.3) do not normally require acceptance criteria in Clause 19.3.4 of ASME SA530 2007?
Dave Moffat
Plant Design Engineering
David.moffat@opg.com<mailto:David.moffat@opg.com>
905 839 1151 x 2167
-----------------------------------------
THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED
RECIPIENT(S) AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED,
PROPRIETARY AND/OR CONFIDENTIAL. If you are not the intended
recipient, you are hereby notified that any review, retransmission,
dissemination, distribution, copying, conversion to hard copy or
other use of this communication is strictly prohibited. If you are
not the intended recipient and have received this message in error,
please notify me by return e-mail and delete this message from your
system. Ontario Power Generation Inc.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment