Re: [MW:13076] Charpy Impact Test requirement for P91

Mr Asif,

Charpy test is required to find the metal behavior at cryogenic temperatures, since your operating temperature is higher than zero temperature, this impact test is not  required.

With regards
 
 
T.Mahendran,
QA/QC Engineer,
Tabouk - KSA,
--- On Sun, 11/27/11, ASIF <asifdme@gmail.com> wrote:

From: ASIF <asifdme@gmail.com>
Subject: [MW:13065] Charpy Impact Test requirement for P91
To: "Materials & Welding" <materials-welding@googlegroups.com>
Date: Sunday, November 27, 2011, 4:44 AM

Dear Members!

Project   : Solar Power plant
Service   : Hight Temperature Steam
Material  : P91
Operating temperature range: 37 - 398 Degree Celsius
Construction Code : ASME B31.1
Welding Code       : ASME Sec IX

Do we need to do 'Charpy Impact Test' for procedure qualification of
P91 material?


Regards
ASIF
+971-50

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...