Hi
Even though the design code is ASME B31.3, PQR shall be qualified as per Sec IX.
Pl refer ASME B31.3, Chapter 5 fully , especially 328.2.
Acceptance levels will vary based on your fluid service levels, but qualification shall be as per ASME Sec IX only.
Thanks and Regards,Rameshkannan Devaraj
On Mon, Mar 12, 2018 at 10:09 AM, Raghuram Bathula <raghurambathula@gmail.com> wrote:
The design Code (B31.3 in this case takes precedence over Section IX, when there is a difference.On Mon, 12 Mar 2018 at 08:35, Ramesh <rameshkannandevaraj@gmail.com> wrote: Hi Jibin & AllThis is my first Entry to this Group... if any mistakes correct me.. ThanksAs a first step, refer Table QW-451.1 in ASME Sec IX for PQR thickness limits.Based on some Essential / supplementary variables this Minimum or Maximum thickness will vary from this table.For example, refer QW-256 -GTAW welding variable table. u can see QW403.6 , QW 407.4 i.e T limits row and study relevant QW clause which is self explanatoryYour caseQ1) What will be the thickness range qualified is it 10.97 to 16.97 or 5 mm to 16.97 or 5 mm to 21.94.Since your PQR have impact requirement i.e supplementary variable requirements , Your PQR thickness range qualified is 10.97 to 21.94Q2) If i need to qualify a WPS with Thk ranges 5 mm to 25mm which thickness need to be selected .Qualify one PQR (1) with 6 mm thick, this will qualify 3 to 12 mm thkQualify other PQR (2) with 12 mm thick , this will qualify 12 to 24 mm thkQualify other PQR (3) with 25 mm thick, thick will qualify 16 to 50 mm thkSo you will have WPS combining all PQRs with 3 to 50 mm which almost covers all your Fabrication requirement for CS pipes.Hope this helps you...Thanks and Regards,
Rameshkannan Devaraj
On Sun, Mar 11, 2018 at 5:58 PM, Babur Khan <mbabur.bwp@gmail.com> wrote:Dear sir,As per ASME Sec ix QW-403.6Min. T (10.97) mac 2T.Regards,M. Babur Khan LashariSent from my iPhoneOn Sun, 11 Mar 2018 at 13:46, Jibin Philip <jibinphilip123@gmail.com> wrote:Dear All ,Spec - ASME B31.3 (Ed : 2016) & Sec IX (Ed : 2017) ,For PQR-A106 GR B - i have taken 6" pipe Thk - 10.97mm - with impact testQ1) What will be the thickness range qualified is it 10.97 to 16.97 or 5 mm to 16.97 or 5 mm to 21.94.10.97 to 16.97Q2) If i need to qualify a WPS with Thk ranges 5 mm to 25mm which thickness need to be selected .you need to have multiple test couponsRegards ,Jibin--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com .
Visit this group at https://groups.google.com/group/materials-welding .
For more options, visit https://groups.google.com/d/optout .
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment