Monday, March 12, 2018

[MW:27505] Re: Impact Test for Procedure Qualification

Thank you all for your valuable informations , 

Dear Ramesh ji ,

Can u elaborate more for the below comments ,

Qualify other PQR (2) with 12 mm thick , this will qualify 12 to 24 mm thk - 

this pqr can be avoided by using asme interpretations

Regards , 

jibin 
On Sunday, 11 March 2018 12:46:38 UTC+3, Jibin Philip wrote:
Dear All , 

Spec - ASME B31.3 (Ed : 2016)  & Sec IX (Ed : 2017) ,

For PQR-A106 GR B -  i have taken 6" pipe Thk - 10.97mm - with impact test

Q1) What will be the thickness range qualified is it 10.97 to 16.97 or 5 mm to 16.97 or 5 mm to 21.94.

Q2) If i need to qualify a WPS with Thk ranges 5 mm to 25mm which thickness need to be selected .

Regards , 

Jibin 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35536] RANGE ASME SEC IX

Dear All we have qualified WPS for ( ASME SEC IX) 1. BASE plate 8 mm ( 8TO 16 mm RANGE WITH IMPACT )  2 . BASE plate 25 mm ( 16TO 50mm RANGE...