Hi,
Working with European and/or ISO standards, the locations are stated in ISO 13916.
For thickness (t) less than 50 mm, interpass and preheat should be measured at a distance of 4 x t from the grove, however max. 50 mm from it.
For thickness (t) of more than 50 mm, you may end up with a distance of 75 mm
Yours sincerely
Kristian Lund Jepsen
M. Sc. Mech. Eng.
Senior Chief Consultant
Piping, Mecanical and Layout
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Nallavan
Sent: 25. marts 2018 04:34
To: Materials & Welding <materials-welding@googlegroups.com>
Subject: [MW:27564] AWS D1.1- Measuring Preheat and Interpass Temperature location
Dear Experts
Pls refer appl codes/standards and advise correct measuring location for Preheat and Inter-pass Temperature
Question | |||||||
How far groove joint, preheat and inter-pass temperature shall be measured? | |||||||
My understanding:- | |||||||
1-Preheat Temperature shall be measured minimum 3"(75mm) from groove joint | |||||||
2-Interpass Temperature shall be measures maximum 10mm from groove joint |
--