Re: [MW:27537] TOFD in lieu of RT

the joint efficiency does not change. It is the same as in the case of RT.
As per UW-51(a)(4) RT can be replaced by UT under the condition that the thickness is equal or larger than 6mm

2018-03-21 15:50 GMT+02:00 Makrand Sakpal <makrands9@gmail.com>:
Dears,

Our prospective vendor is offering TOFD for category A & B weld joints instead of RT for a process column due to RT room size limitations. Is it acceptable by ASME SEC VII DIV-1? What will be the joint efficiency in this case to be used in calculations?

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.



--
Dr. Georgios Dilintas,
Dipl. Ing. In Aeronautic and Space Engineering
Ph.D in Mechanics of Solids - Computational Mechanics
A.I.S, A.N.I, IRCA Lead Auditor
Welding, Stress Analysis, Corrosion, QA/QC, Failure Analysis, Risk Analysis

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone