Thanks for your suggestion.
Please understand my point. The filler wire readings mentioned in the table(trailing mail) is not from the manufacture's test certificate but from Positive material identification(PMI). In PMI test two parent metals,filler wire showing positive values as T91 but weld metal only not conforming as T91.
We procured other two new batch filler wires from the same manufacturer,welded and checked. It shows positive material for all the four(two parent metal,weld metal,filler wire) as T91.
Regards
Jubair
-- On Tue, Aug 28, 2012 at 10:58 PM, c sridhar <sridhar305@yahoo.com> wrote:
Mr. Md. Jubair,The mistake could have happened due to deficiency in the chemistry of the filler metal used for your welding.
It also happened to us years back, wherein an imported 2.50 Cr -0.5 Mo filler wire was actually found to have less than 1.75 Cr. and more than 35 joints done, were cut and re-welded.
Then onwards we made it a point to evaluate the chemistry, mechanical (if required) properties of the consumables (both filler wires & coated electrodes) used for such sensitive joints like alloy, stainless steel or special materials.Instead of depending blindly upon on the manufacture's Test Certificate , it is always better to cross check the chemistry & mechanical properties independently before using them for welding..Otherwise, It could have been due to choosing a wrong filler wire by the user on the shop floor though AWS classification is printed / punched on it. But it seldom happens.Hence, please be alert in future and re weld the joints if required.Sridhar.,
From: mohamed jubair <kmd.jubair@gmail.com>
To: materials-welding@googlegroups.com
Sent: Tuesday, 28 August 2012 1:55 PM
Subject: [MW:15142] Problem about Positive material Identification(PMI)
Waiting for your valuable suggestions.
Dear all,In our boiler one major problem occurred in Positive Material Identification(PMI) test [Spectrum test].
Description Reheater finishing outlet(RHFO) coil Material T91 Size ΓΈ 63 x 4 Process GTAW only Filler wire ER 90S B9 Filler wire Manufacturer D & H Secheron Preheating °C 185 Rate of Heating °C 100/hr Interpass temp °C 190 Post heating °C 100 PWHT °C 750 Soaking Time 90 minutesAround 800 joints welded in the above approved procedure only. Filler wire, header stub, RHFO coil, weld metal undergone PMI test separately and all show positive material results as T91 except weld metal. Weld metal shows the Chromium content only as (4-7%){Reqd is 8-10.5%}. We can't find how it happened? Our Chinese consultant told to cut and reweld all the joints. But our contractor argued that we followed approved procedure and used approved vendor's consumable only. Please give a solution. Here I have attached one preheating cum PWHT chart of RHFO joints(for 11 joints,5 thermocouples,1 recorder).All 800 joints are not checked yet. Only 40 joints checked and all 40 weld metals shown low Cr Content.Please go through the below readings of one RHFO joint.
Description Filler wire Header stub Weld metal RHFO coil Alloy T91 T91 A-2 T91 Cr 8.94 8.34 5.19 8.68 Mo 0.96 0.90 0.93 0.92 V 0.17 0.17 0.08 0.19 Ti 0.07 0.10 0.04 0.03 Mn 0.60 0.40 0.54 0.63 Fe 87.81 88.11 90.86 87.61 Ni 0.12 0.33 0.20 0.38 Cu 0.02 0.16 0.20 0.16 Nb 0.09 0.08 0.03 0.04 W 0.15 0.00 Thanks & RegardsK Mohamed Jubair--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment