Skip to main content

Re: [MW:15072] RE: 15059] expansion joints

Dear Dr. Gendia
 
Many thanks for your kind response....
 
The problem is I do not have 100 meter distance to do my expansion loop. My client asks me every day to use the available expansion joint in Iraq, which is longitudinal only without lateral. That makes me think about using of an expansion loop to overcome the problem of lateral expansion...
 
Thanks again ....
 
Dr. Eng. Alaa A. Atiyah
Consultant Engineer
Iraq-Basrah
Mobile: +964 (0)7700778992
 


--- On Sat, 8/11/12, eccospi <eccospi@gmail.com> wrote:

From: eccospi <eccospi@gmail.com>
Subject: [MW:15067] RE: 15059] expansion joints
To: materials-welding@googlegroups.com
Date: Saturday, August 11, 2012, 3:49 PM

Dear College

 

To have a proper answer we need to have the ISO of the inlet line with all dimensions and curbs angles , the fixed points and ends , the flow rates and pressure in order to calculate the required expansion joints required.

But if these data would be hard to get in the mean time. Practically least to have the line  diagram between last curb /or fixed joint before Tank inlet.

Any way if you are within 100 meters you could use one expansion Loop for safety.

 

 

Best rgrds

D.eng.A.Aziz Gendia

ecco-spi President & CEO

Mob.: +2012 21 33 956

Fax: +202 2477 8411

e-mail: ecco-spi@gmail.com

 

 

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Dr-alaa Zg
Sent: Saturday, August 11, 2012 12:40 AM
To: materials
Subject: [MW:15059] expansion joints

 

Dear Experts...

 

I need to minimize the number of expansion joints in 8 and 12 inch oil pipe used in feeding up a storage tank with 5000 cubic meters ..... I think the using of loop expansion can solve the problem...... Would you please help me in getting some criteria...

 

 

Dr. Alaa

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...