dear
no,because PWHT is service requirement
H.KASHKOUSHA
From: asad azmi <azmiasadayub@gmail.com>
To: materials-welding@googlegroups.com
Sent: Friday, August 10, 2012 11:45 PM
Subject: [MW:15058] PWHT REQUIREMENT FOR REPAIR OF FILLET WELD
Dear All,
Greetings.
A Vessel is being fabricated as per ASME SEC VIII DIV 1.
Material of the Shell is SA 516 GR 70 HIC - 30 mm Thk.
PWHT of the vessel is already completed. PWHT is a Service requirement.
After PWHT it was found out that FILLET WELD of NOZZLE PAD to SHELL is less than the requiremnt. Nozzle Pad thickness is 30 mm. pad is welded on external surface of the shell.
Actual fillet is 12 mm less than the required fillet size.
Please advice whether Repair ( increase of fillet weld size) can be done without RE- PWHT.
Please give Code reference.
Thanks & Regards
Asad Azmi
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.