Re: [MW:15110] electrode with diff impact temp mixing during welding.

Weld a Test Coupon with same lot number of Electrodes (-29C Impact Tested). and get it Impact tested from lab at -46C. it will solve problem.


On Wed, Aug 22, 2012 at 2:09 PM, Chan, David <David.Chan@exterran.com> wrote:
Mohammed,
I think it is a honest mistake and to avoid future problems, it is advisable to cut it out and re-weldo with full compliance the approved WPS. The responsibility is too huge to shoulder. I think it is an appropriate decision 


Sent from Samsung Mobile



mohd <mohd52100@gmail.com> wrote:


dear experts,

We have land in difficult situtuation due to welders mistakes.

Electrode E7018H4R impact require -46deg but by mistakes welder used
some electrodes E7018H4R -29deg during welding of 3 long seam 25m
(filling n caping)

Materials      516 gr 60    thk 40t.
Process        GTAW+SMAW

 What could be solution? To save joint.
Client already given cut out.

Regards,
Mohammed.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...