Wednesday, August 22, 2012

[MW:15103] electrode with diff impact temp mixing during welding.

dear experts,

We have land in difficult situtuation due to welders mistakes.

Electrode E7018H4R impact require -46deg but by mistakes welder used
some electrodes E7018H4R -29deg during welding of 3 long seam 25m
(filling n caping)

Materials 516 gr 60 thk 40t.
Process GTAW+SMAW

What could be solution? To save joint.
Client already given cut out.

Regards,
Mohammed.

--