Thursday, April 22, 2010

Re: [MW:4932] Re-Certifying Material

The following is reproduced from a standard ASME Manual.

a)            In case material is received to a different Edition / Addenda than that ordered, the QA/QC Engineer shall review the MTR and material markings against the applicable material specification, and if found meeting the requirements, an entry shall be made in the MTR/CMTR "Test Certificate verified as per ASME Sec II, Part…….Edition & Addenda……." and signed & dated.

 

b)            Materials produced to ASTM specifications may be considered as meeting the applicable ASME material specification, if the Edition of ASTM material specification is within the Editions stated in Sec II, Part A or B (as applicable) in the table of 'Guideline on acceptable ASTM Editions'

 

c)            If the Edition of ASTM specification is either earlier or later than those permitted by Section II, the MTR and material markings shall be reviewed by the QA/QC Engineer, against the material specification, to which the material produced and to which the material is certified and if found meeting the requirements, an entry shall be made in the MTR "Test Certificate certified as per ASME Sec II, Part…….Edition & Addenda……." and signed & dated.

AISI materials can be certified only as per UG 10 or PG 10.

arun



On Thu, Apr 22, 2010 at 1:36 PM, Karthik <karthik6684@yahoo.com> wrote:
hi,
this is very simple.When you recertify ASTM material in to ASME,First you check with the ASME Code book shows Acceptable ASTM edition.According to that you check with ASTM material certificate,whether that edition listed in the ASME or not.If listed than it is ok.Finally you have to check this material properties and Stamp "Material Identical with ASME Edition_________Addenda_________ and Signed by QC Engineer or Manager then it shall be Accepted by AI(If you are doing Code Jobs)If not a Code Jobs Shop QC sign is enough.
 
Regards,
 
(Karthik)

Karthikeyan.S
 
Getabec Energy Co.,Ltd.
379,Moo6,Soi8,Nikhomphatana,
Rayong-21180,
Thailand.
Phone: 0066 38 897035-8 (Off)
Fax: 0066 38 897034
Hand Phone: 0066 892512282


--- On Thu, 4/22/10, Ramesh Barot <rameshnbarot@yahoo.com> wrote:

From: Ramesh Barot <rameshnbarot@yahoo.com>

Subject: [MW:4919] Re-Certifying Material
To: "Materials Welding" <materials-welding@googlegroups.com>
Date: Thursday, April 22, 2010, 4:03 PM


Dear All,
 
Pl.give me detailed procedure for re certifying material?
 
Example 1)ASTM to ASME
              2)AISI to ASME/ASTM
              3)ASME to ASME (Different edition)
 
Thanks,
With Best Regards,
Ramesh Barot

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
ARUNACHALAM.A
050-5257122

IT'S BETTER TO LOSE YOUR EGO TO THE ONE YOU LOVE.
THAN TO LOSE THE ONE YOU LOVE ....... BECAUSE OF EGO

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...