Wednesday, April 21, 2010

Re: [MW:4903] PQR position qualified

Dear Avinash,

Yes, 3G Vertical Up qualifies all positions when CVN required.

If CVN is not required , this variable doesnot apply.

Regards,

K.Babu


----- Original Message -----
From: "Avinash" <avinash22285@gmail.com>
To: "Materials & Welding" <materials-welding@googlegroups.com>
Sent: Tuesday, April 20, 2010 11:09 PM
Subject: [MW:4900] PQR position qualified


> Members,
>
> In AWS D1.1, table 4.6 point 6 states that: A 3G vertical up test
> qualifies for all positons. If our PQR testing includes CVN
> requirement, can we go for only 3G vertical test coupon qualifying all
> positons?
> Please clarify.
>
> Regards
> Avinash
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>
> Subscription settings:
> http://groups.google.com/group/materials-welding/subscribe?hl=en
>


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...