Hello Vinayak,
Yes you are correct ASME 31.1 only allows SMLS pipe for boiler external piping, mentioned plate materials are for manufacturing of other items.
Kind regards
Rahul
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Nivendkar Vinayak (Mumbai - Piping)
Sent: vrijdag 16 april 2010 12:13
To: materials-welding@googlegroups.com
Subject: [MW:4825] ASME B 31.1 welded pipe in boiler external piping
Dear all,
As per ASME B 31.1 Anex –A Table A-1 note 1 , it seems that we could not used welded pipe A 671 , A672 for pressure retaining parts of external boiler piping .
But for the same time Plate material A515,A516 is allowed.
Now my query “are welded pipes are not allowed for boiler external piping as per ASME B 31.1.
Kindly reply.
Regards,
Vinayak Nivendkar
____________________________________________________________________________
This email has been scanned for Viruses and Spam. For more information
please contact your local Business Unit Information Security representative.
____________________________________________________________________________
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.