Skip to main content

Re: Fw: RE: Re: [MW:4912] Acceptability of MTC.

Dear All
 
Pipe cap is considered to be a standard item as per ASME Sec. VIII Div. 1, hence marking on the item as required by ASME Sec. II can be the criteria for acceptance.  However, when the MTC is provided by the manufacturer, the same shall be reviewed to ensure meeting with the chemical and physical properties as per Spec. Cu content in this case appeares to be too high and may create problem during welding.  Hence, recheck the material by chemical analysis including Cu at a good lab. 
 
Gopu Nair
 
Vagal <nach_sam@yahoo.com> wrote:

From: Shashank Vagal <nach_sam@yahoo.com>
Subject: Fw: RE: Re: [MW:4910] Acceptability of MTC.
To: materials-welding@googlegroups.com
Cc: "Kehinde Akin" <kehinde.akintulerewa@nigerdock.com>
Date: Wednesday, 21 April, 2010, 3:59 PM

Please see below our material controller's comments.He also wants to know which year Code edition is referred to....

--- On Wed, 21/4/10, kehinde.akintulerewa@nigerdock.com <kehinde.akintulerewa@nigerdock.com> wrote:

From: kehinde.akintulerewa@nigerdock.com <kehinde.akintulerewa@nigerdock.com>
Subject: RE: Re: [MW:4904] Acceptability of MTC.
To: nach_sam@yahoo.com
Cc: shola.adeyemi@nigerdock.com
Date: Wednesday, 21 April, 2010, 3:42 PM

Mr. Shank,

 

I will disagree with the mail below

 

MTC is a requirement of SA20 Para 19.1

 

Dish head shall be checked to conform with UG79 & UG81

 

MTC Shall be verified for conformance with Applicable Edition and Addenda of ASME Sec 11 part A.

 

Regards,

 

Kehinde

 

From: Shashank Vagal [mailto:nach_sam@yahoo.com]
Sent: Wednesday, April 21, 2010 8:13 AM
To: Kehinde Akintulerewa
Subject: Fw: Re: [MW:4904] Acceptability of MTC.

 



--- On Wed, 21/4/10, Arunachalam A <arunvani@gmail.com> wrote:


From: Arunachalam A <arunvani@gmail.com>
Subject: Re: [MW:4904] Acceptability of MTC.
To: materials-welding@googlegroups.com
Date: Wednesday, 21 April, 2010, 12:48 AM

If the vessel is as Per Div-1, and the end cap is a standard one as per ASME B16.9, you do not not require MTC. The end cap can be accepted based on marking as per UG 11 & UG 93. The manufacturer's marking is taken as the certification of materials.

 

arun

 

On Sun, Apr 18, 2010 at 5:59 PM, smruthi mohan <smruthi2007@rediffmail.com> wrote:

Hi.

Anybody please advise me on the below,

we have an 12" End Cap (SA403 WP316L)for an ASME job. But in test certificate there is an additional element content (Cu (0,370))is present in the chemical Analysis. please advice me that we can accept this item or not.

Thanks in advance.

SMRUTHI MOHAN
ENGINEER - MATERIALS.
QICL, FUJAIRAH

 

Error! Filename not specified.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.




--
ARUNACHALAM.A
050-5257122

IT'S BETTER TO LOSE YOUR EGO TO THE ONE YOU LOVE.
THAN TO LOSE THE ONE YOU LOVE ....... BECAUSE OF EGO

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

 


Please know that this email is confidential and should be read by only the intended receipient

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .