Tuesday, May 12, 2015

Re: V/v: [MW:23269] Cracking on bending test

This is general problem in FCAW process. This may not be crack, this is problem of interrun fusion. This problem comes only when u perform bend test. If u perform any NDT test, u will not find anything. Increase welding current for ur desire result.

--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/23b0749e-ccba-4af4-8a3b-44827b9ac0ea%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35241] Overlay welding defects

Dear Sir, The below is another type of defect,Mostly these two type of defects we faced. Regards, R.Gowtham. On Wed, Sep 11, 2024 at 1:42 PM...