The NDT in lieu of Pressure Test is a PED approach and not a Code approach
best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS PIRAEUS - GREECE
Tel: +30 210 40 63 113 /4 /5
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
Vino Varghese ---20/05/2015 13:19:23---Dear All, Does ASME B 31.1 dictates alternate NDT method in lieu of Pressure test if
From: Vino Varghese <vinopvarghese@gmail.com>
To: materials-welding@googlegroups.com
Date: 20/05/2015 13:19
Subject: [MW:23301] ASME B 31.1 / Pressure test cannot be performed
Sent by: materials-welding@googlegroups.com
Dear All,
Does ASME B 31.1 dictates alternate NDT method in lieu of Pressure test if it cannot be performed? There are times during in service repair work for Boiler external piping where Pressure test cannot be performed due to unavailability of isolation. Please share your expertise.
Regards
Vino Varghese
--
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAM7oz7BYx41cTAFgXkZfzBPbX%3DVOo7mmXnE1Qc04FO%2BsDcX5LA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.
This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com
No comments:
Post a Comment