Skip to main content

Re: [MW:21908] Pneumatic test instead of hydrotest

Dear Mohammed 

switch over is allowed safety is the concerns

345.5.1 Precautions. Pneumatic testing involves
the hazard of released energy stored in compressed gas.
Particular care must therefore be taken to minimize the
chance of brittle failure during a pneumatic leak test.
Test temperature is important in this regard and must
be considered when the designer chooses the material
of construction. See para. 345.2.2(c) and Appendix F,
paras. F323.4 and F345.5.1.
345.5.2 Pressure Relief Device. A pressure relief
device shall be provided, having a set pressure not
higher than the test pressure plus the lesser of 345 kPa
(50 psi) or 10% of the test pressure.
345.5.3 Test Fluid. The gas used as test fluid, if not
air, shall be nonflammable and nontoxic.
345.5.4 Test Pressure. The test pressure shall be
not less than 1.1 times the design pressure and shall not
exceed the lesser of
(a) 1.33 times the design pressure
(b) the pressure that would produce a nominal pressure
stress or longitudinal stress in excess of 90% of the
yield strength of any component at the test temperature

Regards
Sathiyanarayanan

On Tuesday, 16 September 2014 07:44:07 UTC+3, hpi001 wrote:
Dear Madam / Sir,

Thank you for your e-mail but unfortunately I'm out of office till September 22. I don't have access to my e-mail account during this period and therefore can't answer and /or react on any e-mail.
If necessary I will reply a.s.a.p. after I'm back in my office.

Best Regards,

Herman Pieper



--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...