Dear All,

I have one doubt.

In section IX A-number specified for mild steel is 1 and when we see the chemistry of the filler metal in section II part c the range specified is going beyond the specified limit Si - 1% and Mn - 1.6% as per section IX.  if a batch of carbon steel filler metal having Sil 1.03 and Mn. 1.6 % then in which A-number we can consider and shall we qualified a new procedure for this particular batch and which A-number we will assign.

Thanks in advance,
Manoj.

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35241] Overlay welding defects