When the chemical composition of a ferrous filler metal is not matching one of the A-Nos given in the table referenced in QW-404.5, then you have to make reference to the classification of that filler metal.
Then your essential variable is not the A-No any more, but this chemical composition.
Then your PQR is covering WPSs when, besides the other essential and supplementary essential variables, the chemical composition of the filler metal is within the same range
- best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS HELLAS
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
(See attached file: Dilintas_George.vcf)
"'Prakash Hegde' via Materials & Welding" ---23/09/2014 13:57:57---Hi! As per ASME sec IX
From: "'Prakash Hegde' via Materials & Welding" <materials-welding@googlegroups.com>
To: materials-welding@googlegroups.com
Date: 23/09/2014 13:57
Subject: Re: [MW:21979] A-number as per ASME section IX.
Sent by: materials-welding@googlegroups.com
Hi!
As per ASME sec IX
the A No is expected Weld chemistry range and for filler metal F no is designated
Moreover for CS welding, while selection of Filler ,you have to give importance to Mechanical properties and not exact matching of chemistry
Regards
Hegde prakash
--------------------------------------------
On Tue, 23/9/14, Manoj John <manojacgnr@gmail.com> wrote:
Subject: [MW:21978] A-number as per ASME section IX.
To: materials-welding@googlegroups.com
Date: Tuesday, 23 September, 2014, 2:11 PM
Dear All,
I have one doubt.
In section IX A-number specified for mild steel
is 1 and when we see the chemistry of the filler metal in
section II part c the range specified is going beyond the
specified limit Si - 1% and Mn - 1.6% as per section IX.
if a batch of carbon steel filler metal having Sil 1.03
and Mn. 1.6 % then in which A-number we can consider and
shall we qualified a new procedure for this particular batch
and which A-number we will assign.
Thanks in advance,Manoj.
--
To post to this group, send email to
materials-welding@googlegroups.com
To unsubscribe from this group, send email to
materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members
personel views and meant for educational purposes only,
Users must take their own decisions w.r.t. applicable
code/standard/contract documents.
---
You received this message because you are subscribed to the
Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails
from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com
No comments:
Post a Comment