Re: Re: [MW:9521] CS in place of LTCS

@ CS in place of LTCS
 
i mean to know if we are taking well care of low temperature/using impact tested CS ,then CS would be a better metallurgy than LTCS or not because LTCS is having (Cr+Ni) ,certainly having better properies than CS in terms of corrosion????
 
Any experience of repl;acing LTCS tubes with CS tubes in heat exchanegrs is appreciated.
 
 
regards.


On Thu, Jan 27, 2011 at 1:42 PM, muthu barathi <muthu_barathi@rediffmail.com> wrote:


Hi,

SA 516 Grades all comes under (SPECIFICATION FOR PRESSURE VESSEL
PLATES,
CARBON STEEL, FOR MODERATE- AND LOWER TEMPERATURE SERVICE)

while ordering you have to mention the requirement in supplementary
S5. Charpy V-Notch Impact Test,then you will get LTCS.




On Thu, 27 Jan 2011 12:50:01 +0530 wrote

>
Dear All,

Can anybody tell me theMaterial A516Gr. 55 is C.S orLTCS?
Thank's,
>

>
>
>REMEMBER ME IN UR PRAYERS !
>*******(¨`·.·´¨) (¨`·.·´¨)********
>********`·.¸(¨`·.·´¨)..·´*********
>*********** `·.¸.·´************

>Best Regards,
>Ayaz Merhmood
>FEDC Dept.
>I-G-D HABSHAN-5 PROJECT
>DESCON ENGINEERING (UAE)
>Mobile :
+971-50-1926232
>www.descon.com.pk

>

>


From: yogesh
>To: Materials & Welding
>Sent: Thu, January 27, 2011 10:22:53 AM
>Subject: [MW:9512] CS in place of LTCS
>
>Can we replace LTCS with CS if temperature minimum expexted is
>-20DegC,process fluid;Coolwing water???
>
>--
>To post to this group, send email to materials-
welding@googlegroups.com
>To unsubscribe from this group, send email to materials-
welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.
>






--
>
To post to this group, send email to materials-welding@googlegroups.com
>
To unsubscribe from this group, send email to materials-
welding+unsubscribe@googlegroups.com
>
For more options, visit this group's bolg at http://materials-
welding.blogspot.com/
>
The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.
>


Dear Sir,





Thanking You,

Honesty is the best Policy

With Warm Regards,

Muthu Barathi P
Mobile No:00962788269821 (Jordan)
00962775401951

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .