Thursday, January 27, 2011

Re: [MW:9517] CS in place of LTCS

hi

If cooling water , then the CS pipe tested with impact and the
temperature should be more than your fluid temperature . if the fluid
temperature is (-))10 deg C then your base metal should be at least (-)
20 deg C. in this way your CS is there then you may replace or you have
to go for LTCS.


On Thu, 27 Jan 2011 12:39:26 +0530 wrote
>Can we replace LTCS with CS if temperature minimum expexted is

-20DegC,process fluid;Coolwing water???



--

To post to this group, send email to materials-welding@googlegroups.com

To unsubscribe from this group, send email to materials-
welding+unsubscribe@googlegroups.com

For more options, visit this group's bolg at http://materials-
welding.blogspot.com/

The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.



Dear Sir,





Thanking You,

Honesty is the best Policy

With Warm Regards,

Muthu Barathi P
Mobile No:00962788269821 (Jordan)
00962775401951

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...