Excludes 2”
Refer para 11.1 “For pipe NPS 2 and under a sufficient length of pipe shall stand being bent cold through 90°…………..”
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Vino Varghese
Sent: Monday, January 31, 2011 4:24 PM
To: materials-welding@googlegroups.com
Subject: [MW:9597] Flattening Test for SA 106
Dear Experts,
Refer to Section 12.0(Flattening Test) of SA 106, ASME Sec II Part A.
This Section states that - " For Pipe over NPS 2 a section of pipe not less than........"
Question: Does the above Interpretation includes 2" or excludes 2" for the Flattening Test?
Do provide the reference of ASME/ASTM which supports the Interpretation.
The MTC recieved does not reflect the Flattening Test.( Material - 2", Sch 80, SA 106 Gr.B for Sour Service)
Hope to see as usual co-operation from everyone in Material Group.
Thanks & Regards
Vino P Varghese
Doha-Qatar
No comments: