Monday, January 31, 2011

[MW:9562] PCM (Parameter Crack Measurement)

Dear All,

 

Please suggest me any information about PCM (Parameter Crack Measurement).

 

Regards,

Firman

 

 

1 comment:

Unknown said...

ExxonMobil recommend a cracking parameter value of 0.23 for NACE defined sour service. The formula used is as follows:

Pcm = C + Si/30 + (Mn+Cu+Cr)/20 + Ni/60 + Mo/15 + 5B

[MW:35536] RANGE ASME SEC IX

Dear All we have qualified WPS for ( ASME SEC IX) 1. BASE plate 8 mm ( 8TO 16 mm RANGE WITH IMPACT )  2 . BASE plate 25 mm ( 16TO 50mm RANGE...