Monday, January 31, 2011

[MW:9562] PCM (Parameter Crack Measurement)

Dear All,

 

Please suggest me any information about PCM (Parameter Crack Measurement).

 

Regards,

Firman

 

 

1 comment:

Unknown said...

ExxonMobil recommend a cracking parameter value of 0.23 for NACE defined sour service. The formula used is as follows:

Pcm = C + Si/30 + (Mn+Cu+Cr)/20 + Ni/60 + Mo/15 + 5B

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...