As per ASME Sec II part C, E7018 electrode impact test up to minus 30 degrees C. You can use E7018-1 for minus 46 degree C.
Regards,
K.Ramalingeshwara rao.
On Sun, May 30, 2010 at 9:17 PM, Vijay <k.vijayaraj@gmail.com> wrote:
Dear All,
Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at
-46 oC) or we need to use other??
Kindly clarify.
Regards,
Vijay,
Advanced Oilfield Technology Company,
Oman.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.