Wire IQI
Used to assess sensitivity ; quality of technique
Pl refer DIN 54109 (1962); ISO 1027 Wire set 1-7; set 6-12; set 10-16 (1,7,6,12,10,16 represent wire numbers)
3 sets - each set having 7 wires (overlapping with adj set) arranged in GP
usually 2% or lesser value of sensitivity is required for general applications
Smaller no 1% indicates higher sensitivity -critical applications
wire dia wire No
mm
3.2 ............... 1
3.2 ............... 1
2.5 ............... 2
2.0 ............... 3
1.6 ...............4
1.25 ...............5
1.0 ...............6
0.8 ...............7
---------------------------
1.0 ..............6
0.8 ...............7
0.63 ...............8
0.50................9
0.40..............10
0.32..............11
0.25...............12
-----------------------------
0.40..............10
0.32..............11
0.25..............12
0.20 .............13
0.15 .............14
0.125............15
0.10 .............16
---------------------------
Regds
MSR
--------------------------------------------------------------------------------------