Hi Vijay,
According to ASME Sec-II Part-C 2007 ed, SFA-5.1 , Table 3 ( Charpy Impact requirement),E7018 testing requirement at -30 deg C & E7018-1 testing requirement at -45 deg C, if your requirement is at -46 deg C, then it will not be suitable.
Regards,
On Mon, May 31, 2010 at 10:56 AM, raghurambathula@gmail.com <raghurambathula@gmail.com> wrote:
You can use E7018-1, however if your service is non corrossive (non NACE or no restriction on Ni %), E 7018-C3L, 8016-C1 could be a betterchoice.
Sent from my Nokia phone
-----Original Message-----
From: Vijay
Sent: 30/05/2010 11:47:20 pm
Subject: [MW:5303] Electrode for SA516 Gr.70 Material.
Dear All,
Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at
-46 oC) or we need to use other??
Kindly clarify.
Regards,
Vijay,
Advanced Oilfield Technology Company,
Oman.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
Sukamal
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment