Monday, May 31, 2010

Re: [MW:5308] Electrode for SA516 Gr.70 Material.

Dear Mr. Vijay,
 
You should use E 7018-1 electrode which give imapct at -50 C where as the E 7018 is gauranted for -29 C only.
 
Regards
 
N.V. PRASAD
WELDING ENGINEER,
VELOSI CERTIFICATION, QATAR.
00974 5974703

On Sun, May 30, 2010 at 9:17 PM, Vijay <k.vijayaraj@gmail.com> wrote:
Dear All,

Can we used E7018 electrode for SA516 Gr.70 material (Impact Tested at
-46 oC) or we need to use other??

Kindly clarify.

Regards,
Vijay,
Advanced Oilfield Technology Company,
Oman.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...