Hi

 

Please see the extract from OS-101, highlighting PWHT requirements. It's under Appendix-C.

 

Incoloy 825 or 625 clad pipes(depending  on the type of alloy used as CRA) are extremely tricky to fabricate. DNV-OS-F101 is a very detailed and extremely stringent standard to follow.

 

Thanks.

 

 

P.Goswami.P.Eng, IWE.

Welding & Metallurgical Specialist

Linkedin: https://www.linkedin.com/in/pradip-goswami-2999855/

Email:pgoswami@quickclic.net,pradip.goswami@gmail.com

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Rajendra Jadhav
Sent: December 5, 2017 5:11 AM
To: materials-welding@googlegroups.com
Subject: [MW:27121] 40 mm thickness CRA Pipe Qualifying New PQR as per DNV OS F101 Edition.2013

 

Dear Experts,

 

I am going to qualify new PQR for 40 mm thk CRA Pipe ( 3 mm Incoloy P-45 + 37 mm CS P-1)

as per the spec DNV OS F101 Edition.2013 

So there is requirement for PWHT ?

And what are the Destructive testing & NDT required.

 

Pls Suggest

 

Regards,

Rajendra Jadhav 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.


Virus-free. www.avg.com

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...