Sunday, December 31, 2017

Re: [MW:27244] Aluminum welding 6061-T6 mechanical test bend failure

What is your joint configuration ? what is the purpose ?

Regards,

Johnson Prabu

On Saturday 9 December 2017, 10:31:47 AM GMT+3, Sathish Kumar <sathishmech04@gmail.com> wrote:


Dear All
Thanks for the feedback.

I have tried with fillerwire ER4043 also in trial basis. But same problem we have facing.

Wrap around bend test 16T is followed for bend test. Ultra high purity argon used for welding. Spray transfer mode is followed with current 190-220 Amps, Volt 22-24, HI- 0.9KJ/mm with no weaving.


But facing same problem. Any other inputs need to be added, kindly Clarify


--