Dear Experts,
-- I am going to qualify new PQR for 40 mm thk CRA Pipe ( 3 mm Incoloy P-45 + 37 mm CS P-1)
as per the spec DNV OS F101 Edition.2013
So there is requirement for PWHT ?
And what are the Destructive testing & NDT required.
Pls Suggest
Regards,
Rajendra Jadhav