Pl refer DNV OS F101 for Pipeline and API RP 2A for structural . Min 3" seggration . Most of the project specifications give the requirement , some time the staggering in top by 90 degree .
Best Regards,
Francis Lobo
----- Original Message -----
From: (PBR)P.BalajiRajan
To: materials-welding@googlegroups.com
Sent: Sun, 31 Oct 2010 00:57:28 +0530 (IST)
Subject: [MW:7959] Longitudinal weld seam staggering
Dear colleagues In any code details given regarding Longitudinal weld seam staggering requirements of adjoining pipes if so please forward, Here By, P.BalajiRajan, |
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.