Golden Joint mean Tie in Joint.normally it will come on Piping final
joint . in this joint after welding you can not test hydrostatic test.
So you have to go for double NDT for volumetric such as RT / UT and MPT
/ DPT . After successful carrying out these test you can release the
joint for charging lines.
On Sat, 30 Oct 2010 12:45:30 +0530 wrote
>Dear all,
can any one explain the golden joint welding , NDT and inspection
requirement with Code references.
Regards,
Gulam Kader
--
>
To post to this group, send email to materials-welding@googlegroups.com
>
To unsubscribe from this group, send email to materials-
welding+unsubscribe@googlegroups.com
>
For more options, visit this group's bolg at http://materials-
welding.blogspot.com/
>
The views expressed/exchnaged in this group are members personel views
and meant for educational purposes only, Users must take their own
decisions w.r.t. applicable code/standard/contract documents.
>
Dear Sir,
Thanking You,
Honesty is the best Policy
With Warm Regards,
P Muthu Barathi