Skip to main content

Re: Re: [MW:7962] No of Welders


Dear Mr. Das,
First of all, my appologies for refering a wrong para of API1104. Read 6.1 for 621.
I don't think it mandatory to have 2 welders on pipes above 12", I couldn't find any thing to support this requirement in API 1104. Whereas in Section IX it is allowed to qualify more than one welder on a single test coupon. Refer QW-306.
It is not mandatory to use two welders in pipes larger than 12" in Section IX also.

Regards,
Dr. Paulose John
QA/QC Manager
Unisis Engineering
KSA

On Sun, 31 Oct 2010 08:08:06 +0530 Arun Das wrote
>
Dear Dr.John,
As a custom for above 12" pipe we will be using 2 welders for the welding process. It is so done because of heat input and distribution factors I beleive, but my question was that do this is stated as mandatory in any of the codes or standards.
I am having 1104 20 th edition of November 2005 with me. API 1104:2007. is the modifications??
Thanks and regards,
>
Arun S Das

>

>

From: Dr. Paulose John <drpaulosejohn@rediffmail.com>
>To: materials-welding <materials-welding@googlegroups.com>
>Sent: Sat, 30 October, 2010 4:07:56 PM
>Subject: Re: Re: [MW:7943] No of Welders
>

> Dear Mr. Arun,
>
>Minimum number of welders to be qualified by one WPS is - One welder. The welder who performs the PQR coupen welding is automatically becomes qualified. Please refer 2nd para of QW 301.2 of Section IX:2010 and para 621 of API 1104:2007.
>
>Regards,
>Dr. Paulose John
>QA/QC Manager,
>Unisis Engineering,
>Saudi Arabia
>.
>On Sat, 30 Oct 2010 14:15:07 , No ID Specified wrote
>
To my knowledge there is no limit for number of welder qualificationupon one WPS, You can qualify as many as per to the requirement for your project.
Here By,
P.BalajiRajan,
-------Original Message-------
From: Arun Das
Date: 10/28/10 17:39:52
Subject: [MW:7911] No of Welders
Sir,
Minimum number of welders to be qualified upon one WPS is mentioned in SEC 1X or API 1104.
We are using PIPE,16"X0.375"WT STD SCH API 5L X52
Thanksinadvance
with regards,
>
Arun S Das

>
FREE Animations for your email - by IncrediMail! Click Here!

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>
>

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

>

--
>To post to this group, send email to materials-welding@googlegroups.com
>To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
>For more options, visit this group's bolg at http://materials-welding.blogspot.com/
>The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
>

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...