Dear;
you can refer sec 341 of b 31.13 for excess penetration.
From: KASHKOUSHA <kashkousha1@yahoo.com>
To: materials-welding@googlegroups.com
Sent: Mon, October 25, 2010 7:10:01 PM
Subject: Re: [MW:7791] EXCESS PENETRATION
Dear P.Mahendran
thanks for prompt reply but what clause no in b31.3
H.KASHKOUSHA From: mahendran p <pmahe_79@yahoo.co.in>
To: materials-welding@googlegroups.com
Sent: Mon, October 25, 2010 3:15:07 PM
Subject: Re: [MW:7788] EXCESS PENETRATION
Dear Kashkousa, Its depends on the wall thickness. for Example, if wall thk is <=6 mm then EP is 1.5mm >6 < =13mm the EP is 3 mm Thk & rgds, P.Mahendran --- On Mon, 25/10/10, KASHKOUSHA <kashkousha1@yahoo.com> wrote:
|
--