Dear Expert,
As, Pipe OD is 10.3mm only...even after using four specimens, total weld length become 130mm only....it means radiography is not possible.
Can we go for bend test to qualify welders??? If yes how many bends to be taken..I believe its four....wt say???
RGDS
From: Harikrishnan N S <hari.qaqc@gmail.com>
To: materials-welding@googlegroups.com
Sent: Wednesday, 14 August 2013 10:05 AM
Subject: [MW:18424] Re: Welder qualification on small OD pipe
Rohit
On Tuesday, August 13, 2013 5:16:28 PM UTC+8, Rohit mn wrote:
-- As per Sec IX, the NDE requirement (for performance qualification) is a weld length of 150 mm or 4 test coupons at least. Ref. QW 302.2
Regards
Harikrishnan
On Tuesday, August 13, 2013 5:16:28 PM UTC+8, Rohit mn wrote:
Dear Experts,Can we qualify welders on 10mm OD Pipe (1.73mm wt) by radiography....If Yes how many specimen to be radiograph...If No What are the other option as per ASME Sec. IX
Welding procees is GTAW.
--
Rh
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
Comments