Dear
The temp is -31.1OC
Thanks & Regards
Hoang Van Duc
QC site
Gorgon Heavy Lift and Tie In project
(+84)0943266655
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of nguyen anh tuan
Sent: 17 August, 2013 3:36 PM
To: materials-welding@googlegroups.com
Subject: [MW:18451] CVN Test Temperature Reduction AWS D1.1
Dear Experts
I have question about using sub-sized specimen for CVN test
Testing temperature following specification is -20oc ,Plate thickness is 8mm and specimen sized is 10x5
My question How much temperature will apply for testing (AWS D1.1)
“4.36.7 When sub-sized specimens are required, and the
width of the specimen across the notch is less than 80%
of the base metal thickness, the test temperature shall be
reduced in conformance with Table 4.15, unless otherwise
specified in the contract documents
Thanks in advance
Tuan
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
No comments:
Post a Comment