Hi Mr Mohammad,
Normally SAW, no BT Burn through will not come as the root and hot pass will be
already welded. This will act as back up and while welding there will be fill
up passes and capping only required. No chances of BT in SAW so it is not
mentioned in API 5 L . Even though due to any untoward circumstances any BT
created then the same shall be repaired.
On Sun, 18 Sep 2011 19:23:44 +0530 wrote
>DEAR ALL
NOTHING IS MENTIONED ABOUT WELD DEFECTS BURN THROUGH IN API 5L 44TH ADDITION
FOR PSL2 PIPES.
I WANT TO NO IF BURN THROUGH DEFECTS COME BY SAW WELDING IT IS ACCEPTABLE OR
REJECTABLE FOR PSL2 PIPES.
REGARDS
MOHAMMAD SAJID ALAM
INSPECTION ENGINEER
AICO-DAMMAM
MOBILE:-0534077860
--
>
To post to this group, send email to materials-welding@googlegroups.com
>
To unsubscribe from this group, send email to materials-
welding+unsubscribe@googlegroups.com
>
For more options, visit this group's bolg at http://materials-
welding.blogspot.com/
>
The views expressed/exchnaged in this group are members personel views and
meant for educational purposes only, Users must take their own decisions w.r.t.
applicable code/standard/contract documents.
>
Dear Sir,
Thanking You,
Honesty is the best Policy
With Warm Regards,
Muthu Barathi P
Mobile No:00962788269821 (Jordan)
00962775401951
Treat yourself at a restaurant, spa, resort and much more with Rediff Deal ho jaye! --
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: