Dear Mr. Azmi,
What is the thickness of the plate material, and are these separate rolled plates or manufactured from coil?
In case of production from coil a minimum of 2 tensile specimens need to be tested for each coil, so in this case 2 specimens would be acceptable. See note 1 chapter 3.2 of SA283.
Met vriendelijke groeten / Best Regards
Herman Pieper
Pieper Quality Support & Inspection
Phone: +31 (0)521 380083
Fax: +31 (0)84 7539225
Cell: +31 (0)6 51691215
www.pieper-qsi.nl
Van: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] Namens asad azmi
Verzonden: woensdag 28 september 2011 12:29
Aan: materials-welding@googlegroups.com
Onderwerp: [MW:12567] Tension Test Requirement for SA 283 Gr.C plates
Dear All,
Greetings.
As per MTC for the plates material - SA283GR C, for a single Heat number( 10K22884) total 15 Nos of plates are supplied having plate no. 15942
Description of Goods- Hot rolled steel plates with sheared edges. Plates are in Non Heatreated condition.
MTC is showing only 2 tension test results.
Please clarify whether only two tension test are acceptable OR there shall be 15 nos of tension test for 15 plates.( 1 tension test for each plate)
Thanks & Regards
Asad Azmi
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.