Sunday, September 25, 2011

[MW:12520] PQR by E7010 4mm electrode

Dear Experts,
 
We have carried out PQR by E7010 4mm electrode for fill passes but it was unsuccessful in root bend test.We have carried out same process in repair PQR which is successful.

So plz give me your advice which will help me in next PQR.
 
Thank you...
MPK

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...