Saturday, September 17, 2011

Re: [MW:12472] Reduce Magnetic filed a the start of welding

Dear Abhishek,

Change the direction of joint if joint position is East-West. Than keep the joint in North-South.

Regards,

MANISH YADAV
Sr. Inspector
Bureau Veritas

On Fri, Sep 16, 2011 at 8:52 PM, ABHISHEK GHOSH <ghoshabhishekmech@gmail.com> wrote:
Dear Experts, 

Can anybody suggest  some remedial action to be taken to eliminate magnetic field occurring at the start of the welding as its producing LOF at the start of weldiing ? 

Process : GMAW Downhill 
Material : API 5L X 52 
Preheat temp : 70 deg C 

Kindly suggest . 


With regards. 

ABHISHEK GHOSH 

 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
 
 
MANISH YADAV
8609649383,8890122779

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...