Monday, June 27, 2011

Re: [MW:11496] Re: Temper embrittlement

Thank you for giving reply but P5C also contains more than 0.15% Mo & still need temper embrittlement test but not for P5B!

On Mon, Jun 27, 2011 at 1:53 PM, mohd.qce <mohd52100@gmail.com> wrote:
Dear maulik,

Temper embritllement can be prevented by keeping  sulfer an phosferous
at low level and also addition of Mo(<0.15% min) will prevent temper
embritllent.

As far as my interpretaion SecIX all P5B materials have a more than
0.5%Mo. so that not required.

It really intersting subject..if get more info please share with us.

regards,
mohd.


On Jun 26, 11:28 am, "Maulik H. Thakkar" <mlkthakk...@gmail.com>
wrote:
> Dear all,
>
> Why temper embrittlement test is not required for P5B materials as per
> API 934?

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
Regards,
 
Maulik H. Thakkar
Larsen & Toubro, Hazira

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...