Wednesday, June 29, 2011

Re: [MW:11517] SA82 F316L Flanges

Dear Experts,
           
            Can anybody tell SA 182 F316L 1" Flanges we received without Solution annealing, Is it acceptable? Please let me know code reference.(ASME SEC II A).
 
Thanks and Regards,
Kumar.
Singapore.


No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...