Yes you have to requalify your procedure only impact at -40 deg c. No other option
br,
msms
On Wed, Jun 22, 2011 at 4:08 PM, <vimal.mistry@suzlon.com> wrote:
Dear All.
I have PQR with -20 deg Impact & Values are 180 to 194 J Now I require
PQR with -40deg Impact so can I go through same PQR with -40deg
Impact or I should qualify another.
If it's acceptable then which std/ spec. can be use as ref.
Vimal
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.