Thursday, June 23, 2011

Re: [MW:11444] PQR conversation -20 deg to -40 deg

Yes you have to requalify your procedure only impact at -40 deg c. No other option
 
br,
msms

On Wed, Jun 22, 2011 at 4:08 PM, <vimal.mistry@suzlon.com> wrote:
Dear All.
I have PQR with -20 deg Impact & Values are 180 to 194 J Now I require
PQR with -40deg Impact so can I go through same PQR with  -40deg
Impact or I should qualify another.
 If it's acceptable then which std/ spec. can be use as ref.

Vimal

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...