Friday, April 6, 2012

Re: [MW:14075] Impact test report of PTC

Dear Shadab, salam
 
We have welded PTC with qualified wps with E70S2 @ minus 48deg C,
 
Test was carried out for weld,
 
Ali
 
 
-------Original Message-------
 
Date: 05/04/2012 09:44:27
Subject: Re: [MW:14064] Impact test report of PTC
 

Dear Ali,
The consumable for tig Filler metal ER70S2 is not suitable for impact test @-48 degrees.
Also want to know the heat input and location of charpy impact test.

Regards
Shadab

On Apr 5, 2012 7:50 AM, "Aly" <mhaskar.aly@gmail.com> wrote:
Low temp vessel PTC for head to shell c-seam; Head : Cap SA420WPL6, Pipe: SA333 Gr 6; Filler metal ER70S2+ E7018-1; GTAW+ SMAW process.
 
PTC used as filler metal is not SFA classified for low temp -48deg C
 
Impact test results: 18, 14, 12 Joules test piece size 10 x 7.5 x 55 @ -48deg C;
 
Average value required for 10x 7,5x55 is 15joule; single specimen 2/3 x 15: 10joule
 
Reference ASME SEC VIII Div-1 2011a UG 84 & UCS 67
 
Dear Expert,
Let me have your advice whether these results are acceptable.
 
Thanks
Aly
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...